Table 5-1 Front Panel LEDs (continued)
DescriptionStatusLED
At least one MP is installed and activeGreen
(solid)
MP Status
No MPs are installed or at least one is installed but not activeOff
Cabinet overtemp condition existsRed (flashing)
Cabinet shutdown for thermal reasonsRed
(solid)
Cabinet fan slow or failed, master slave failover.Yellow
(flashing)
FPGA detects no MPs present or functioningYellow
(solid)
Cell power onGreen
(solid)
Cell 0 and Cell 1
Cell power offOff
Cell fault. Cell powered off due to power problem or HPMC/MC
event from cell
Red
(solid)
Cell fault warning
Latches not latched, LPM not ready, VRMs reporting not good or
OT Cell fan slow/failed
Yellow
(flashing)
Cell not presentYellow (Solid)
User requests locator ON and specifies (1 - 72) hour off timeout.
Default timeout is 24 hours.
Blue
(flashing)
Locate
Timeout. Or user requests locator off.Off
Bulk Power Supply LEDs
There is a single three-color LED on each bulk power supply.
Server LED Indicators 123