4. Reinsert the bottom controller into the enclosure, closing the controller module handle and tightening
the captive retaining thumbscrew.
The bottom controller powers on.
5. Monitor the boot process through the OS serial port connection on the Windows system. When the
uBoot main menu appears, as shown in uBoot main menu, press Esc to stop the autoboot
countdown.
Figure 54: uBoot main menu
6. Use the arrow keys to highlight Boot from USB thumb drive. Press Enter.
The controller reboots and opens the SV3200 Field Imaging utility.
Figure 55: SV3200 Field Imaging utility
7. Type REIMAGE in all capital letters.
The controller takes 10 to 15 minutes to complete the reimaging process.
When the reimage process completes, the utility will display the following message:
Reimaging this controller completed successfully!
8. To reboot the bottom controller, type REBOOT in all capital letters.
9. Monitor the boot process through the OS serial port connection on the Windows system. When the
uBoot main menu appears, as shown in
uBoot main menu, press Esc to stop the autoboot
countdown.
124 Reimaging a StoreVirtual 3200 Storage