10. Power down the bottom controller using the recessed recovery/power button.
The blue UID LED lights up while the controller shuts down. When all LEDs are off, the controller has
powered down.
11. Remove the bottom controller from the enclosure by loosening the captive retaining thumbscrew and
swinging out the controller module handle.
12. Repeat 3 on page 123 through 11 on page 125 for the top controller.
13. Disconnect the Windows system and USB-to-micro-USB cable from the controller, and then remove
the USB thumb drive.
14. Reinsert both controllers into the enclosure, closing the controller module handles and tightening the
captive retaining thumbscrews.
Both controllers power on.
The system is now reimaged and ready for configuration setup. Following configuration setup, reapply
any licenses that were in effect prior to reimaging.
Reimaging a StoreVirtual 3200 Storage 125