No. Procedure
1 Powering off the FIC/HIC
2 Checking the Configuration
10.2.2 Powering off the FIC/HIC
Do as follows on the router to be configured.
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
preplug slot slot-id
The FIC/HIC is powered off.
----End
10.2.3 Checking the Configuration
Action Command
Check the registration of the
FIC/HIC.
display device
After the power-off operation, run the display device command to check the displayed
information. Check the items under 'Slot', to see whether there is a '*'. The '*' indicates that
the operation succeeds, and you can pull out the FIC/HIC. For example:
<Quidway> display device
Quidway 's Device status:
Slot # Type Online Status Role
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0 RPU Present Normal NA
1 1POS155 Present Normal HIC
2 1GE Present Normal HIC
3 4CE1 Present Normal FIC
4 8CE1 Present Normal FIC
5 2FE Present Normal FIC
6 4SA Present Normal FIC
7 1CPOS Present Normal FIC