5 User Management
Quidway NetEngine20/20E
Configuration Guide - Basic Configurations
5-8 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 05 (2010-01-30)
Step 2 Run:
user-interface [ ui-type ] first-ui-number [ last-ui-number ]
The user interface view is displayed.
Step 3 Run:
user privilege level level
The priority of the user interface is set.
----End
5.2.6 Configuring Modem Attributes
Do as follows on the router that the user logs in to:
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
user-interface aux 0
The user interface view is displayed.
Step 3 Run:
modem timer answer seconds
The interval between the system receiving the Ring signal and waiting for CD_UP is set. The
time it takes from off-pick of the Modem to carrier detection is set
Step 4 Run:
modem auto-answer
The automatic answer is set.
Step 5 Run:
modem [ both | call-in ]
The incoming and outgoing calls are set.
----End