Page #202 background image
10 Router Maintenance
Quidway NetEngine20/20E
Configuration Guide - Basic Configurations
10-6 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 05 (2010-01-30)
Before restarting the router, run the save command to save the current configuration file.
Do as follows on the router to be configured.
Select the following configuration, according to the situation.
z
To restart the router immediately, run:
reboot
z
To restart the router at specific time, run:
schedule reboot { at exact-time | delay interval }
10.3.4 Performing the Master/Slave Switchover
NE20 contains only one RPU, so NE20 does not support this function.
Do as follows on the router to be configured.
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
slave switchover { enable | disable }
The router is configured to allow or forbid the master/slave switchover forcibly.
If the master/slave switchover needs to be carried out through the CLI, you need to configure
the router to allow the switchover in this step.
Step 3 Run:
slave auto-update config
The automatic synchronization to the slave RPU is configured.
This step is optional. By default, the system automatically synchronizes the data to the slave
RPU.
Step 4 Run:
quit
The CLI returns to the system view.
Step 5 Run:
save
The configuration file is saved.
Step 6 Run:
system-view

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway NetEngine 20 series and is the answer not in the manual?

Huawei Quidway NetEngine 20 series Specifications

General IconGeneral
BrandHuawei
ModelQuidway NetEngine 20 series
CategoryNetwork Router
LanguageEnglish

Related product manuals