MAP 0500:
After Board or Battery Exchange on NAS Based on 6563
Attention: If you have changed the board, ensure that you have received the
corresponding BIOS code. Otherwise contact your support structure.
001
Power on the Nways Switch administration station and the display using their
respective power ON/OFF switches located on the front panels.
A count of the computer memory appears at the upper-left corner of the display.
Is there an error detected?
Yes No
002
Continue with Step 005.
003
Continue with Step 004.
004
If an error is detected, a message appears requesting an action. Select
Continue, then press Enter.
Follow the prompts to continue until the Configuration/Setup Utility window
appears.
On the Configuration/Setup Utility window, an arrow points to the area where
the configuration has been modified. See “Appendix B. Nways Administration
Station Configuration / Setup Utility for 6563 Model 65U” on page B-1 to check
the configuration and correct it if necessary (check the date and time even if no
arrow points to them).
At the end of configuration, a message asks you if you want to save your
changes.
Select YES and press the Enter key to start the system.
Continue with Step 006 on page 5-17.
005
At the end of the boot, the Nways Switch Desktop window should appear.