EasyManuals Logo

IBM E027SLL-H - Tivoli Monitoring - PC User Manual

IBM E027SLL-H - Tivoli Monitoring - PC
310 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #199 background imageLoading...
Page #199 background image
There can be a variety of factors that lead to a failed history collection:
v The size of the history data file affects the amount of time it takes the agent to
read the file.
v The amount of data the agent is trying to send to the monitoring server.
v The bandwidth of the communications (for example, a slow data rate).
Situations with attributes from more than 1 group not supported with
autonomous agent
When using autonomous agent in Manage Connected Mode, creating situations
with AND and OR logic, and using values from two different attribute groups, the
traps do not list the predicates in an expected way.
If you have defined a situation that attempts to combine attributes across more
than 1 attribute group, this is not currently supported by any autonomous agent
processing mode or private situations. The monitoring server performs the
evaluation of situations having combined attribute groups. This can be either from
embedded situations, or two or more attribute groups in the same predicate, for
example, WHERE USER=abc AND LOCALTIME=today.
Failure when importing situation xml file edited with WordPad
If you edit an xml file for a situation using WordPad, and then import the situation
(tacmd createsit-i xml), the command fails. If you edit the xml file using
Notepad, it works correctly. Use Notepad to edit situation xml files.
Printer details of another system are displayed on the Tivoli Enterprise
Portal
When connecting to a system remotely, printers on that local system can be seen
from the Tivoli Enterprise Portal on the remote system. You should be aware that
by using a remote desktop, printer information might be displayed in the Tivoli
Enterprise Portal and shared with others.
CTIRA_MAX_RECONNECT_TRIES environment variable is now
obsolete
The agent now attempts communication with a monitoring server until a
connection is successfully established. There is no longer a limit on the number of
connection attempts. If the CTIRA_MAX_RECONNECT_TRIES environment
variable is specified, it is accepted, and results in the agent reverting to the
previous behavior of there being a limit on connection attempts. A trace message is
also produced, indicating that this variable is obsolete.
If you specify this variable and the number of connection attempts to the
monitoring server exceeds CTIRA_MAX_RECONNECT_TRIES, the agent attempts
to shutdown. If the Agent Management Services Watchdog is running, it
immediately restarts the agent. If you want the agent to shutdown when
CTIRA_MAX_RECONNECT_TRIES is exceeded, this Watchdog process must be
disabled. Use the AMS Stop Management action to disable this watchdog process.
Chapter 10. Monitoring agent troubleshooting 181

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM E027SLL-H - Tivoli Monitoring - PC and is the answer not in the manual?

IBM E027SLL-H - Tivoli Monitoring - PC Specifications

General IconGeneral
BrandIBM
ModelE027SLL-H - Tivoli Monitoring - PC
CategorySoftware
LanguageEnglish

Related product manuals