v STATE - minimum detail.
v DETAIL - medium detail.
v ALL - maximum detail.
For example, ’KBB_RAS1=’ERROR (UNIT:kfaot STATE)’
3. Save the file.
4. Recycle the monitoring server for the trace to take effect.
5. The monitoring server log can be found in install_dir/logs/
hostname_ms_nnnnnnn.log where is a time stamp. There might be multiple files
with different time stamps in the logs directory.
Setting the trace option for the IBM Tivoli Enterprise Console
Situation Update Forwarder
If your monitoring environment is configured for the IBM Tivoli Enterprise
Console, you can forward situation events to the Tivoli Enterprise Console event
server. You can also view events on the event server through the Tivoli Enterprise
Portal. If you want to forward situation events to and view updates from IBM
Tivoli Enterprise Console in the Tivoli Enterprise Portal, you can set the trace for
the Situation Update Forwarder on the IBM Tivoli Enterprise Console event server.
The default trace setting is low. You can edit the trace setting using the sitconfig
command.
$BINDIR/TME/TEC/OM_TEC/bin/sitconfig.sh update
fileName=configuration_file_name logLevel=trace_level
where:
configuration_file_name
The file name of the actively loaded configuration file as indicated by the
situpdate.properties file.
trace_level
Specifies the level of trace as low, med,orverbose.
Use the IBM Tivoli Enterprise Console Situation Update Forwarder trace facility to
diagnose problems with the IBM Tivoli Enterprise Console Situation Update
Forwarder. The trace for the IBM Tivoli Enterprise Console Situation Update
Forwarder is set during installation. The acceptable values include:
v low
v med
v verbose
The default trace value is low. If you change the trace level after the Situation
Update Forwarder is started, you must restart the Situation Update Forwarder for
the change to take effect. There are two trace files:
synch_trace.log
is always created.
synch_msg.log
is created if an error occurs while running the Situation Update Forwarder.
Run the following command to set the trace levels:
$BINDIR/TME/TEC/OM_TEC/bin/sitconfig.sh update
fileName=configuration_file_name logLevel=trace_level
where:
52 IBM Tivoli Monitoring: Troubleshooting Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM E027SLL-H - Tivoli Monitoring - PC and is the answer not in the manual?

IBM E027SLL-H - Tivoli Monitoring - PC Specifications

General IconGeneral
BrandIBM
ModelE027SLL-H - Tivoli Monitoring - PC
CategorySoftware
LanguageEnglish

Related product manuals