Table 3-5 (Page 10 of 10). Firmware Checkpoints.
Checkpoint Description Action/
Possible Failing FRU
E213 Initial memory configuration. 1. Replace the memory card (See
notes on 3-1.)
2. Replace the System Board.
See the note on 3-29.
E214 Memory test. Replace the memory card (See
notes on 3-1.) See the note on
3-29.
E216 Copy ROS into RAM. Setup
Translation and C environment.
Replace the memory card (See
notes on 3-1.) See the note on
3-29.
E220 Final memory configuration. Go to “MAP 1540: Minimum
Configuration” on page 2-17.
E299 Start C code execution. See the note on 3-29.
E3xx Memory test See “Memory Test Hang Problem”
on page 3-42.
E440 Validate NVRAM, initialize partitions
as needed.
1. Verify that the system and
Service Processor firmware
levels are at the current release
levels, update as necessary.
2. Replace the memory card (See
notes on 3-1.) See the note on
3-29.
E441 Generate /options node NVRAM
configuration variable properties.
1. Verify that the system and
Service Processor firmware
levels are at the current release
levels, update as necessary.
2. Replace the memory card (See
notes on 3-1.) See the note on
3-29.
E442 Validate NVRAM partitions. 1. Verify that the system and
Service Processor firmware
levels are at the current release
levels, update as necessary.
2. Replace the memory card (See
notes on 3-1.) See the note on
3-29.
E443 Generate NVRAM configuration
variable dictionary words.
Suspect a system firmware problem
if this problem persists. Verify that
the system firmware is at the
current release level, update as
necessary. See the note on 3-29.
Chapter 3. Error Code to FRU Index 3-41