The SP can dial a pre-programmed telephone number in the event of an IPL
failure. The SP issues an error report with the last reported IPL status indicated
and any other available error information.
Update Operator Panel
The SP displays Operator Panel data on the ASCII terminal if a remote
connection is active.
Environmental Monitoring
Environmental Monitoring is now controlled by the SP instead of the base
system, with expanded error recording and reporting.
System Firmware Surveillance (Heartbeat Monitoring)
The SP will monitor and time the interval between system firmware heartbeats.
Responding to System Processor Commands
The SP will respond to any command issued by the system processor.
Runtime Phase
This phase includes the tasks that the SP performs during steady-state execution of
the operating system.
Environmental Monitoring
The SP monitors voltages, temperatures and fan speeds (on some servers).
Responding to System Processor Commands
The SP will respond to any command issued by the system processor.
Run-Time Surveillance (Heartbeat Monitoring)
If the device driver is installed and surveillance enabled, the SP will monitor the
system heartbeat. If the heartbeat times out, the SP places an outgoing call.
This is different from the Bringup Phase scenario where two reboot attempts are
made before placing an outgoing call.
Appendix E. Service Processor Operational Phases E-3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 7025 F50 Series and is the answer not in the manual?

IBM RS/6000 7025 F50 Series Specifications

General IconGeneral
BrandIBM
ModelRS/6000 7025 F50 Series
CategoryServer
LanguageEnglish

Related product manuals