Step 2010-2
One of the following conditions exist. Take the action described.
1. You have an hdisk that has no associated pdisk.
a. Issue the system cfgmgr command.
b. Retry the Configuration Verification service aid.
c. If the problem remains, a software error has probably occurred. Call your
support center for assistance.
2. You have a pdisk that has no associated hdisk.
a. Run diagnostics (using system verification mode) to the pdisk.
b. If you get a 5 digit SRN, go to Table A-1 on page A-6 and follow the actions
described.
If you do not get a 5 digit SRN, the disk formatting may be incompatible with
the system (the disk was formatted on a different type of using system).
1) Format the pdisk.
2) Issue the system cfgmgr command
3) Retry the Configuration Verification service aid.
3. If the problem remains, a software error has probably occurred. Call your
support center for assistance.
2-38 Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 7025 F50 Series and is the answer not in the manual?

IBM RS/6000 7025 F50 Series Specifications

General IconGeneral
BrandIBM
ModelRS/6000 7025 F50 Series
CategoryServer
LanguageEnglish

Related product manuals