Update System Firmware: This option allows you to update your system
firmware. Note that you must insert a diskette containing the firmware update image
after you see the following confirmation screen.
à ð
.--------------------------------------------------------------.
| This selection will update your System Firmware. Do you want |
| to continue? Press Y(Yes) N(No). |
--------------------------------------------------------------'
á
ñ
Firmware Recovery:
If a troubleshooting procedure has indicated that the firmware
information in your system unit has been corrupted, then you must perform a
firmware recovery.
To perform a firmware recovery, do the following:
1. Locate your firmware update diskette.
2. Using another system unit, rename the
*.img
file on the firmware update diskette to
precover.img
3. Make sure your system unit is turned off.
4. Insert the firmware recovery diskette into your system unit.
5. Turn on your system unit.
6. When the keyboard indicator appears, press the 1 key on the system console
ASCII terminal.
7. When the System Management Services appear, choose Utilities and perform a
System Firmware Update as described above.
Select Console: Selecting this option allows you to define which display is used
by the system for system management.
5-38 Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 7025 F50 Series and is the answer not in the manual?

IBM RS/6000 7025 F50 Series Specifications

General IconGeneral
BrandIBM
ModelRS/6000 7025 F50 Series
CategoryServer
LanguageEnglish

Related product manuals