MAP 2010: SSA Hot-Swap Disk Drive–Start
This MAP is the entry point to the MAPs for the SSA Hot-Swap Disk Drive. If you
are not familiar with these MAPs, read “How to Use These MAPs” on page 2-35 first.
If you get a 5 digit SRN but are not sure which SSA Hot-Swap Disk Drive may be
defective, run the Link Verification Service Aid.
You might have been sent here because:
The system problem determination procedures sent you here.
Action from an SRN list sent you here.
A problem occurred during the installation of an SSA Hot-Swap Disk Drive
module.
Another MAP sent you here.
A customer observed a problem that was not detected by the system problem
determination procedures.
Step 2010-1
Have you been sent to this MAP from the Configuration Verification service aid?
NO Go to “Step 2010-3” on page 2-39.
YES Go to “Step 2010-2” on page 2-38.
Chapter 2. Maintenance Analysis Procedures 2-37