System Power Control Menu
à ð
SYSTEM POWER CONTROL MENU
1. Enable/Disable Unattended Start Mode:
Currently Disabled
2. Ring Indicate Power-On Menu
3. Reboot/Restart Policy Setup Menu
4. Power-On System
5. Power-Off System
98. Return to Previous Menu
99. Exit from Menus
á
ñ
Enable/Disable Unattended Start Mode
This option may be used to instruct Service Processor to immediately power-on
the server after a power failure, bypassing power-on password verification.
Unattended Start Mode can also be set via SMS Menus. It is intended to be
used on servers that require automatic power-on after a power failure.
Ring Indicator Power-On Menu
Ring Indicate Power-On is an alternate method of dialing in, without establishing
a Service Processor session. If the system is powered off, Ring Indicate
Power-On is enabled, the server is powered on at the predetermined number of
rings, If the server is already on, no action is taken. In either case, the telephone
call is not answered. The caller receives no feedback that the server
powered-on. The Ring Indicator Power-On Menu and defaults are shown
below:
à ð
Ring Indicator Power-On Menu
1. Ring Indicate Power-On :
Currently Disabled
2. Number of Rings :
Currently 6
98. Return to Previous Menu
á
ñ
B-12 Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 7025 F50 Series and is the answer not in the manual?

IBM RS/6000 7025 F50 Series Specifications

General IconGeneral
BrandIBM
ModelRS/6000 7025 F50 Series
CategoryServer
LanguageEnglish

Related product manuals