EasyManuals Logo

IBM RS/6000 7025 F50 Series User Manual

IBM RS/6000 7025 F50 Series
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #69 background imageLoading...
Page #69 background image
Step 2010-3
Have the system diagnostics or problem determination procedures given you a
5 digit SRN for the SSA Hot-Swap Disk Drive?
NO Go to “Step 2010-4.”
YES Go to “Service Request Numbers (SRNs)” on page A-3.
Step 2010-4
If the system diagnostics are available, go to “Step 2010-5.”
If the stand-alone diagnostics are available, but the system diagnostics are not
available, run them, then go to “Step 2010-5.”
If the system diagnostics and stand-alone diagnostics are not available, go to “Step
2010-1” on page 2-37.
Step 2010-5
Run the diagnostics in the problem determination mode.
Note: Do not run the advanced diagnostics, because errors are logged on other
using systems that share the same loop.
Did the diagnostics give you an SRN for the SSA Hot-Swap Disk Drive?
NO Go to “Step 2010-6” on page 2-40.
YES Go to “Service Request Numbers (SRNs)” on page A-3.