Table 3-1 (Page 16 of 24). Firmware Error Codes.
Error Code Description Action / Possible Failing FRU
2BA00321 Service Processor reports +12V Under
Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00322 Service Processor reports -12V Over
Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00323 Service Processor reports -12V Under
Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00324 Service Processor reports 5V Standby
Over Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00325 Service Processor reports 5V Standby
Under Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00326 Service Processor reports PCI
Expansion Card 5V Over Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00327 Service Processor reports PCI
Expansion Card 5V Under Voltage
Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00328 Service Processor reports PCI
Expansion Card 3.3V Over Voltage
Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00329 Service Processor reports PCI
Expansion Card 3.3V Under Voltage
Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00330 Service Processor reports PCI
Expansion Card +12V Over Voltage
Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00331 Service Processor reports PCI
Expansion Card +12V Under Voltage
Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00332 Service Processor reports PCI
Expansion Card -12V Over Voltage
Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00333 Service Processor reports PCI
Expansion Card -12V Under Voltage
Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00334 Service Processor reports Generic
Slow Shutdown request.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
Chapter 3. Error Code to FRU Index 3-17

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 7025 F50 Series and is the answer not in the manual?

IBM RS/6000 7025 F50 Series Specifications

General IconGeneral
BrandIBM
ModelRS/6000 7025 F50 Series
CategoryServer
LanguageEnglish

Related product manuals