Table 3-1 (Page 18 of 24). Firmware Error Codes.
Error Code Description Action / Possible Failing FRU
2BA00343 Service Processor reports Locked fan -
Fast Shutdown request fan number 4.
1. Replace fan 4.
2. If problem persi.ts, replace Power
Supply.
3. Replace I/O Board. (See notes on
3-1.)
2BA00350 Service Processor reports Generic
Immediate Shutdown request.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00351 Service Processor reports Generic AC
power loss EPOW.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00352 Service Processor reports Loss of AC
power (outlet).
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00353 Service Processor reports Loss of AC
power (power button).
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00399 Service Processor reports Unsupported
value in EPOW.
1. Check EPOW cabling on SCSI or
SSA Backplanes.
2. Replace I/O Board. (See notes on
3-1.)
40100005 A loss of system power detected. Possible main power loss. If not,
replace power supply.
40100007 Immediate shutdown. Possible main power loss. If not,
replace power supply.
40110001 Power Supply fail. 1. Check power cable to P2
connector on I/O Board.
2. Power supply.
3. I/O board. (See notes on 3-1.)
4. Service processor.
40110002 Voltage not detected on either
processor card.
Replace power supply.
40110003 Voltage not detected on one processor
card. (If the system is running, refer to
the AIX error log to find out which
processor card is failing. If the system
is not running, refer to the Service
Processor error log.)
Replace CPU card.
40111002 An unknown power problem detected. 1. Power supply.
2. I/O board. (See notes on 3-1.)
3. Service processor.
40111022 A high 5.0 voltage reading detected. 1. Power supply.
2. CPU card.
Chapter 3. Error Code to FRU Index 3-19