EasyManua.ls Logo

IBM Storwize V7000 - Page 190

IBM Storwize V7000
204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
• The combined power and cooling module exhausts air from the rear of each canister.
Ensure that your environment falls within the ranges that are shown in Table 34 on page 160.
Table 34. Temperature requirements
Environment
Ambient
temperature
Altitude Relative humidity
Maximum wet bulb
temperature
Operating
5°C to 35°C (5°C to
40°C for 2076-24F )
41°F to 95°F
(41°F to 104°F for
2076-24F )
0 - 2133 m
(0 - 7000 ft)
8% to 80%
noncondensing
23°C (73°F)
5°C to 30°C
(41°F to 86°F)
2134 - 3048 m
(7001 - 10000 ft)
Non-operating
1°C to 50°C
(34°F to 122°F)
-305 to 12192 m
(-1000 to 40000 ft)
8% to 80%
noncondensing
27°C (80°F)
Storage
1°C to 60°C
(34°F to 140°F)
5% to 80%
noncondensing
29°C (84°F)
Shipping
-40°C to 60°C
(-40°F to 140°F)
5% to 100%
condensing, but not
precipitating
Dimensions and weight requirements for rack installation
Ensure that space is available in a standard 19" rack that is capable of supporting the enclosure. The rack
rail kits support racks with either threaded round or square rail mounting holes. The following table lists
the dimensions and weights of the expansion enclosures.
Table 35. Physical characteristics of the expansion enclosures
Enclosure Height Width Depth
Maximum weight
Drive ready
(without
drive
modules)
Fully
congured
(with drive
modules)
2076-12F or 2076-24F
87 mm (3.46
in.)
483 mm
(19.0 in.)
556 mm (21.9
in.)
16.7 kg (36.8
lb)
25.0 kg (55.1
lb)
160 Storwize V7000 : Gen3 Quick Installation Guide for MTM 2076-724, 2076-U7B, 2076-12F, 2076-24F, and
2076-92F

Table of Contents

Other manuals for IBM Storwize V7000