8-10 TS3400 Tape Library Maintenance Information
9. Select a Device, and press F7=Commit from the following panel. You must press
F7=Commit after selecting the drive.
10. Enter the Filename in the destination field. (Example: /dev/rfd0 +/). You must
press F7=Commit to write the file to the diskette.
IBM Tape Device Service Aid Menu 700000
Select One of the Service Aids to be performed
Force Microcode Dump
Perform a microcode dump of the system. The dump is stored in
the device.
After the dump is performed it must be read using Read Dump.
Read Dump
Transfer a dump from the tape device to a host file, diskette or
a tape cartridge.
Microcode load
Download microcode from host file or diskette to tape device via
SCSI bus.
Error Log Analysis
Analyze system error log for device.
F3=Cancel F10=Exit
IBM Tape Device Selection Menu. 900000
Select One of the devices listed below.
NAME LOCATION TYPE
rmt2 00-05-01-10 IBM 3592 Tape Drive and Medium Changer
rmt3 00-05-01-30 IBM 3592 Tape Drive and Medium Changer
F3=Cancel F7=Commit F10=Exit