Chapter 12. Message Retrieval at the Host 12-3
LABEL: TAPE_ERR2
IDENTIFIER: 476B351D
Date/Time: Fri May 4 08:42:26 DFT
Sequence Number: 1665
Machine Id: 0046083B4C00
Node Id: risc4
Class: H
Type: PERM
Resource Name: smc0
Resource Class: tape
Resource Type: 3577
Location: P1.1-I3/Q1-W5003013D38321011-L1000000000000
VPD:
Manufacturer................IBM
Machine Type and Model......3577-TL
Serial Number...............0000000F00341003
Device Specific.(FW)........0009
Description
TAPE DRIVE FAILURE
Probable Causes
TAPE DRIVE
Failure Causes
TAPE
TAPE DRIVE
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
Detail Data
SENSE DATA
0C00 0000 A500 0000 100F 1010 0000 0000 0102 0000 7000 0400 0000 000A 0000 0000
1501 0000 BE00 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
Table 12-3. Sense data example 1
Hex Description
A5
70
04
1501
SCSI Command (in this case Move Medium).
Byte 0 of Library Sense Data (Valid Data).
Sense Key (in this case Hardware Error).
ASC/ASCQ (additional sense code/additional sense code qualifier), in this case a Mechanical
positioning error.