v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, Type 7377 server,” on page 125 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code Description Action
305000A RTC date/time is incorrect
1. Adjust the date and time settings in the Setup utility, and
then restart the server.
2. Reseat the battery.
3. Replace the following components one at a time, in the
order shown, restarting the server each time:
a. Battery
b. (Trained service technician only) System board
3058001 System configuration invalid
1. Run the Setup utility, and select Save Settings.
2. Run the Setup utility, select Load Default Settings, and
save the settings.
3. Reseat the following components one at a time in the
order shown, restarting the server each time:
a. Battery
b. Failing device (if the device is a FRU, then it must be
reseated by a trained service technician only)
4. Replace the following components one at a time, in the
order shown, restarting the server each time:
a. Battery
b. Failing device (if the device is a FRU, then it must be
replaced by a trained service technician only)
c. (Trained service technician only) System board
3058004 Three boot failures
1. Undo any recent system changes, such as new settings or
newly installed devices.
2. Make sure that the server is attached to a reliable power
source.
3. Remove all hardware that is not listed on the
ServerProven Web site.
4. Make sure that the operating system is not corrupted.
5. Run the Setup utility, save the configuration, and then
restart the server.
6. See “Problem determination tips” on page 122.
3108007 System configuration restored to
default settings
Information only. This is message is usually associated with
the CMOS battery clear event.
3138002 Boot configuration error
1. Remove any recent configuration changes that you made
in the Setup utility.
2. Run the Setup utility, select Load Default Settings, and
save the settings.
Chapter 3. Diagnostics 35

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3630 M3 7377 and is the answer not in the manual?

IBM x3630 M3 7377 Specifications

General IconGeneral
Product FamilySystem x
Machine Type7377
Max Processors2
ChipsetIntel 5520
Memory Slots12 DIMM slots
ProcessorIntel Xeon 5600 series
MemoryUp to 192 GB
RAID SupportRAID 0, 1, 10, 5, 50
Network Interface2 x Gigabit Ethernet
Power SupplyHot-swap, redundant
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware

Related product manuals