PSK FFT Scope Averaging (Default: OFF)
Sets the FFT scope waveform averaging function from
2 to 4 or OFF.
Recommendation!
Use the default or smaller number FFT scope wave-
form setting for tuning.
PSK FFT Scope Waveform Color
(Default: (R) 51 (G) 153 (B) 255)
Sets the color of the FFT scope waveform.
• The color is set in the RGB format.
• Push [
t u](F)
to select R (Red), G (Green) and B
(Blue). Rotate [MAIN DIAL] to adjust the ratio from
0 to 255.
• The color is displayed in the box beside the RGB
scale.
PSK AFC Range (Default: ±15 Hz)
Selects the AFC (Automatic Frequency Control) func-
tion operating range between ±15 Hz (default) and ±8
Hz.
NOTE: The AFC function may not tune the signal
properly when a weak PSK signal is received.
PSK Time Stamp (Default: ON)
Turns the time stamp (date, transmission or reception
time) display ON or OFF.
• ON: Displays the time stamp.
• OFF: Does not display the time stamp.
PSK Time Stamp (Time) (Default: Local)
Selects the Clock display for the time stamp.
• Local: Selects the time that is set in “Time (Now).”
• UTC*: Selects the time that is set in “CLOCK2.”
* The name of Clock 2 may differ, depending on
the“CLOCK2 Name” setting (p. 14-3). “UTC” is the
default name of CLOCK2.
NOTE: The time won’t be displayed when “OFF” is
selected in “PSK Time Stamp” above.
PSK Time Stamp (Frequency) (Default: ON)
Selects the operating frequency display for the time
stamp.
• ON: Displays the operating frequency.
• OFF: Does not display the operating frequency.
NOTE: The frequency won’t be displayed when
“OFF” is selected in “PSK Time Stamp” above
• PSK decode set screen
[EXIT/SET] [MAIN DIAL](F) Function keys
Operating PSK (Continued)
D
PSK decode set mode
This Set mode is used to set the FFT scope setting,
time stamp setting, and so on.
q
Display the PSK decode screen, then push
[<MENU1>](F).
DECODE [F-3] <MENU1> [F-1] Displays <MENU2>
• The function menu changes to Menu 2.
Push [SET](F). w
• The PSK decoder set screen is displayed.
Push [ e p](F) or [q](F) to select the desired item.
Rotate [MAIN DIAL] to select the desired setting. r
• Hold down [DEF](F) for 1 second to select the default
setting.
• Push [t u](F) to select the set contents for some
items.
Push [EXIT/SET]. t
• Exits the Set screen.