EasyManua.ls Logo

Icom IC-7851 - CC Set Screen; Display Set Screen; Ref Adjust

Icom IC-7851
279 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15-10
15
SET MODE
LCD Unit Bright (Default: 50%)
Adjusts the LCD brightness.
• Range: 0 (dark) to 100% (bright) (in 1% steps)
Backlight (Switches) (Default: 80)
Adjusts the key backlight brightness.
• Range: 1 (dark) to 100 (bright) (in 1 steps)
Display Type (Default: A)
Sets the display type to A or B.
Display Font (Default: Basic (1))
Selects the font for the frequency readout.
Options: Basic (1), Basic (2), Basic (3), Italic (1), Italic
(2), Italic (3), Round (1), Round (2), Round (3)
Meter Response (Default: MID)
Sets the meter needle response speed to SLOW, MID
or FAST.
Meter Type (Normal Screen)
(Default: Standard)
Sets the S/RF meter type for the normal display to
Standard, Edgewise or Bar.
Meter Type (Expand Screen) (Default: Bar)
Sets the S/RF meter type for the expanded display to
Standard, Edgewise or Bar.
Meter Peak Hold (Bar) (Default: ON)
Turns the meter peak hold function ON or OFF.
Memory Name (Default: ON)
Turns the memory name indication in the memory
mode ON or OFF.
• ON: The programmed memory name is displayed
above the frequency display.
• OFF: Memory name is not displayed, even if en-
tered.
Display set screen
External Meter Level (M) (Default: 50%)
Sets the output level to the external meter (Main band).
• Range: 0%–100% (in 1% steps)
Approximately 1.2 V (full-scale) at the 50% (default) setting.
(impedance: 4.7 k)
External Meter Level (S) (Default: 50%)
Sets the output level to the external meter (Sub
band).
• Range: 0%–100% (in 1% steps)
Approximately 1.2 V (full-scale) at the 50% (default) setting.
(impedance: 4.7 k)
REF IN/OUT (Default: OFF)
Selects the transceiver’s reference frequency signal source.
• IN: Uses an external reference signal.
Turn OFF the power, and then turn ON to make
the setting effective.
NOTE: If the applied reference signal is off
frequency, or no signal is applied, the IC-
7851 will not properly operate. In that case,
select “OFF” or “OUT,” and then reboot the
IC-7851
• OFF: Does not input/output the reference signal.
• OUT: Outputs the internal reference signal to the
connected equipment(s).
REF Adjust
Adjusts the internal reference frequency.
• Range: 0%–100% (in 1% steps)
NOTE: The default setting differs slightly, depending
on the transceiver.
ACC set screen (continued)

Table of Contents

Other manuals for Icom IC-7851

Related product manuals