15-13
15
SET MODE
Calibration Marker (Default: OFF)
Turns the reference frequency calibration marker ON
or OFF.
• OFF: Turns OFF the marker.
• ON: Turns ON the marker.
Beep (Conrmation) (Default: ON)
Turns the confirmation beep ON or OFF.
• OFF: Turns OFF the beep.
• ON: Sounds the beep when a key is pushed.
If the Beep Level is set to "0%" on the Level
set screen, no beep sounds.
Beep (Band Edge) (Default: ON (Default))
Turns the band edge beep ON or OFF.
If the Beep Level is set to "0%" on the Level set
screen, no beep sounds.
• OFF:
Turn OFF the band edge beep.
• ON(Default):
Beep sounds on the band edge.
• ON(User):
The beep, which is selected in the Band edge
screen, sounds. (p. 4-15, P4-16)
• ON(User) & TX Limit:
The beep, which is selected in the Band edge
screen, sounds. The transmitting frequency is lim-
ited in the range between upper and lower band
edge. (p. 4-15, p. 4-16)
Beep Sound (MAIN) (Default: 1000Hz)
Sets the key-touch beep frequency on the Main band.
• Range: 500 Hz–2000 Hz (in 10 Hz steps)
If the Beep Level is set to "0%" on the Level set
screen no beep sounds.
Beep Sound (SUB) (Default: 1000Hz)
Sets the key-touch beep frequency on the Sub band.
• Range: 500Hz–2000Hz (in 10 Hz steps)
If the Beep Level is set to "0%" on the Level set
screen no beep sounds.
Others set screen
TX Power Limit (Default: ON)
Turns the TX power limit function ON or OFF.
• OFF: Turn OFF the function.
• ON: Limits the TX power for each mode and
band.
The TX power limit screen is displayed when
[LIMIT] is pushed. Adjust the power limit to
between <5 W and 200 W for each selected
band.
TX Delay (HF) (Default: OFF)
Sets the TX delay time on the HF bands.
• Options:
OFF, 10ms, 15ms, 20ms, 25ms, 30ms
If the connected equipment's rise time is slower
than that of the IC-7851, a reflected wave is pro-
duced and it may damage the IC-7851. To prevent
this, set the appropriate delay time so that no re-
flected wave is produced.
Select "OFF" for no rise speed.
TX Delay (50M) (Default: OFF)
Sets the TX delay time on the 50 MHz band.
• Options: OFF, 10ms, 15ms, 20ms, 25ms, 30ms
If the connected equipment's rise time is slower
than that of the IC-7851, a reflected wave is pro-
duced and it may damage the IC-7851. To prevent
this, set the appropriate delay time so that no re-
flected wave is produced.
Select "OFF" for no rise speed.
Time-Out Timer (CI-V) (Default: OFF)
Sets the Time-out Timer for CI-V operation.
This setting is valid only transmitting initiated by a CI-V
command and pushing [TRANSMIT].
• Options: OFF, 3, 5, 10, 20 or 30 minutes
Select "OFF" for no time limit.
Quick Dualwatch (Default: ON)
Turns the Quick Dualwatch function ON or OFF.
• OFF: Turn OFF the function.
• ON: Turn ON the function.
Quick SPLIT (Default: ON)
Turns the Quick Split function ON or OFF.
• OFF: Turn OFF the function.
• ON: Turn ON the function.