6-8
6
SCOPE OPERATION
• Function menu (MENU2)
• Reference level (±0.0 dB)
• Difference spectrum (+20.0 dB, ±0.0 dB, –20.0 dB)
• Display example (+20.0 dB)
• Display example (–20.0 dB)
Reference level
(+20.0 dB)
±0.0 dB
–20.0 dB
+20.0 dB
All signal levels appear stronger.
All signal levels appear weaker.
Reference level
(–20.0 dB)
[EXIT/SET] [MAIN DIAL](F) Function keys
Spectrum scope screen (Continued)
D Adjusting the Reference level
When monitoring a weak signal that is buried in the
noise floor, or monitoring a strong signal but some
stronger signals is nearby, adjust the Reference level
of the screen helps to see these signals.
Even if this setting is changed, it does not affect the
scope input level.
If you want to change the scope input level, set the
Scope attenuator of 10 dB, 20 dB, or 30 dB.
When you adjust the Reference level, the signal
strength for the waterfall also appears to change.
q
Display the Spectrum scope screen, then push
[<MENU1>](F).
SCOPE [F-1] <MENU1> [F-1] Displays <MENU2>
The function menu changes to Menu 2.
Push [REF](F). w
• Displays the Reference level window.
Push again to close the window.
Rotate [MAIN DIAL] to adjust the level. e
• Adjustable range: –20.0 dB ~ +20.0 dB.
Hold down [REF](F) for 1 second to select ±0.0 dB.
Push [REF](F). r
t
To exit the Spectrum scope screen, push [EXIT/SET].
–5.0k
SPECTRUM SCOPE Grid
1k/10dB
+4+3+2+10–4 –3 –2 –1
+5.0k
ATT OFF HOLD
MAIN
CENTER
M S T
–5.0k
SPECTRUM SCOPE Grid
1k/10dB
+4+3+2+10–4 –3 –2 –1
ATT OFF HOLD
MAIN
CENTER
M S T