No LINK LED on topside
unit.
No power on topside or
subsea bottle.
Check power to cannister and
topside unit is on.
No fiber communication
Check correct fiber is
connected.
Staturated fibre reciveres
Using a fiber signal tester,
check if signal is not to high(-
5dB) or not to low(-20dB) in
the fiber going into the
topside unit.
To much attenuation in fibre
Using a fiber signal tester,
check if signal is not to high(-
5dB) or not to low(-20dB) in
the fiber going into the
topside unit.
Topside or subsea unit may be
overheating.
Add extra cooling to the
topside rack.
Submerge the bottle or turn it
off for cooling.