Chapter 10 — Adjustments
100 EasyCoder PF4i User’s Guide (IPL Version)
To return to the factory setting, tighten the screw (+) as far as it
goes and then loosen it (-) four full turns. Test with a piece of
media under the printhead. You should be able to pull it out
without more than just a little resistance.
Printhead Pressure Adjustment Screw
Adjustment screw