Chapter 8 — Troubleshooting
74 EasyCoder PF4i User’s Guide (IPL Version)
Intermec Ready-to-Work Indicator
The readiness of the printer, individually or as a part of a
solution, is indicated by the blue Intermec Ready-to-Work
Indicator (RTW).
If the RTW blinks or is switched off, the printer is not ready.
Further information can be obtained in the display window by
pressing the i key. In case of several errors or similar conditions
occurring simultaneously, only the most significant error is
displayed. Once this error has been cleared, next remaining error
is displayed.
Provided the printer is connected to a network, all conditions
that prevents printing are reported to the Easy ADC Console.
The Easy ADC Console is a PC-based software which allows a
supervisor to monitor all connected devices that have an
Intermec Ready-to-Work Indicator, including handheld
computers, access points, and printers.
Displayed Error Messages and LED Indicators
Error/Event
RTW
Status
Displayed Error
Message
Comment
Operational On Not an error.
Out of paper Blink PAPER OUT
Out of transfer ribbon Blink RIBBON OUT
Transfer ribbon is
installed
Blink RIBBON
FITTED
Head lifted Blink PRINTHEAD UP
Cutter error 1 Blink OPEN&SHUT
CUTTER
Cutter error 2 Blink OPEN&SHUT
CUTTER
Cutter error 3 Blink OPEN&SHUT
CUTTER
Lss too high Blink PAPER FAULT
Lss too low Blink PAPER FAULT
Testfeed not done Blink PAPER FAULT
Press feed not done Blink PRESS FEED