Chapter 5 — Setting Up the Printer
EasyCoder PF4i User’s Guide (IPL Version) 51
Setup Parameters
Serial Communication
The serial communication parameters control the
communication between the printer and the connected computer
or other devices on the serial port.
Make sure the printers communication parameters match the
parameters set up on the connected device and vice versa. If the
printer and host setups do not match, the response from the
printer to host will be garbled.
Baud Rate
The baud rate is the transmission speed in bits per second. There
are 8 options:
1200
2400
4800
9600 (default)
19200
38400
57600
115200
Data Bits
Data bits specifies the number of bits that will define a character.
7 Characters ASCII 000 to 127 decimal
8 Characters ASCII 000 to 255 decimal (default)
Parity
The parity decides how the firmware will check for transmission
errors. There are four options: None (default), Even, Odd, and
Space.
Note: The serial communication parameters have no effect on
parallel or EasyLAN communications.