Chapter 7 Automated RFC 2544 Testing
Running the Classic RFC 2544 test
HST-3000 Ethernet Testing User’s Guide
213
After you specify the final parameter, select OK to run the
test. Proceed to
step 9 on page 213.
9 A screen appears displaying the status of key events for
the test, and a progress indicator appears that shows the
estimated minimum amount of time required for the test to
complete, It also provides a graphical illustration of the
percent already completed.
– To scroll up or down through the events on the screen
line by line, use the up or down arrow key.
– To scroll up or down a page at a time, press Page Up
or Page Down.
The Classic RFC 2544 test is running.
Packet Jitter – the number of trials
– the trial duration (in seconds)
– pass/fail criteria
Frame Loss – the trial duration (in seconds)
– the maximum bandwidth
– the bandwidth granularity (as a
percentage for the step)
Back to Back
Frames
– the number of trials
– the burst granularity
– the maximum trial time
When testing … Specify…
NOTE:
You can stop the test script at any time using the Stop soft
key.