Chapter 7 Automated RFC 2544 Testing
Running the Classic RFC 2544 test
HST-3000 Ethernet Testing Users Guide
213
After you specify the final parameter, select OK to run the
test. Proceed to
step 9 on page 213.
9 A screen appears displaying the status of key events for
the test, and a progress indicator appears that shows the
estimated minimum amount of time required for the test to
complete, It also provides a graphical illustration of the
percent already completed.
To scroll up or down through the events on the screen
line by line, use the up or down arrow key.
To scroll up or down a page at a time, press Page Up
or Page Down.
The Classic RFC 2544 test is running.
Packet Jitter the number of trials
the trial duration (in seconds)
pass/fail criteria
Frame Loss the trial duration (in seconds)
the maximum bandwidth
the bandwidth granularity (as a
percentage for the step)
Back to Back
Frames
the number of trials
the burst granularity
the maximum trial time
When testing … Specify…
NOTE:
You can stop the test script at any time using the Stop soft
key.