Chapter 8 SAMComplete Testing
Running the test
HST-3000 Ethernet Testing User’s Guide
241
11 If desired, you can save the test settings by doing the
following:
a Press the Save soft key.
b Select Save Config.
c Enter a name for the configuration, and then press OK.
Saving the configuration allows you to load the same
settings later, enabling quicker startup time and consistent
setups.
Running the test
After specifying settings, you are ready to run the test.
To run the test
1 Press the Home navigation key.
2 Press the Display soft key and then select SAMCom-
plete.
The SamComplete Summary screen appears. Figure 48
shows a multi-stream test.
3 If testing on an optical interface, press the Action soft key
and then select Laser On.