Chapter 1 Getting Started
Test applications
14
HST-3000 Ethernet Testing User’s Guide
100M Optical
Ethernet monitor
application
When monitoring 100M optical signals, the HST analyzes the
received signal on the R/T 2 SFP port.
Figure 7 illustrates the signal path when monitoring 100M
optical signals.
Thru
applications
Before running Thru applications, in addition to selecting the
Monitor/Thru application for the signal you are testing, you
must specify Thru as the test type (as opposed to the Monitor
type). When configuring a Thru application, you can specify
filter settings for each port, and test results can also be viewed
for each port simultaneously.
When running Thru applications for 10/100/1G electrical and
1G optical signals, the HST monitors the signal on the
receiving port, and then passes it through to the opposite
port’s transmitter.
Figure 7 Monitor application: 100M optical signal path