Chapter 4 IP Testing
Configuring layer 3 IP tests
HST-3000 Ethernet Testing User’s Guide
141
4 If you indicated that you want to specify a frame length for
the traffic, use the left and right arrow keys to go to the
Ethernet configuration menu, and then specify the length.
5 If you need to specify other settings for the test, use the
left and right arrow keys to go to the appropriate configu-
ration menu; otherwise, press the Home key to return to
the Summary Results screen.
The packet settings are specified for transmitted traffic.
Configuring the
traffic load
Before transmitting IP traffic, you can specify the type of traffic
load the unit will transmit (Constant, Bursty, Ramp, or Flood)
in 0.001% increments, beginning at 0.002%. For details on
configuring a traffic load, see
“Configuring the traffic load” on
page 56.
No Yes Flow Label If you are certain the routers
on the circuit support flow
labels for traffic prioritiza-
tion, specify the flow label
using a hexidecimal format
ranging from 0x0 to
0xFFFFF; otherwise, use
the default (0x0).
No Yes Hop Limit Specify the time after which
a packet can be deleted by
any device on a circuit as a
number of hops. The default
Hop Limit setting is 64
hops.
No Yes Next Header Specify the code represent-
ing the type of data carried
in the next header in the
packet using a hexidecimal
format ranging from 0x0 to
0xFF.
IPv4 IPv6 Setting Parameters