Chapter 7 Automated RFC 2544 Testing
Viewing RFC 2544 test results
218
HST-3000 Ethernet Testing User’s Guide
17 If you haven’t already done so, specify the remaining
settings as appropriate for the traffic you are using for the
test:
IP Init (see “Establishing an IPoE connection for IPv4
traffic” on page 122).
IP (see “Specifying IP packet settings” on page 137).
TCP/UDP (see “Configuring layer 4 traffic” on
page 167).
18 Press the Home button to return to the Summary Results
screen.
19 Press the Action soft key, then select Start RFC 2544.
The RFC 2554 Log appears, which displays the status of key
events during the course of the test.
To scroll up or down through the events on the screen
line by line, use the up or down arrow key.
To scroll up or down a page at a time, press the blue
up arrow key at the bottom, and the up or down arrow
key at the top simultaneously.
The RFC 2544 test is running.
Viewing RFC 2544 test results
After running the test, the unit stores a text file and a PDF of
the test results in the following directory:
/results/rfc2544
NOTE:
You can stop the test at any time by pressing the Action
key, and then selecting Stop RFC 2544.