Chapter 7 Automated RFC 2544 Testing
Running the Expert RFC 2544 test
HST-3000 Ethernet Testing Users Guide
217
9 Go to the Frame Length menu, then specify the length for
Frame 1 through Frame 8. The instrument will transmit a
series of frames with each length during the course of the
Throughput test.
10 Go to the Throughput menu, then specify the accuracy,
test duration, frame loss tolerance, and show pass/fail
status settings.
NOTE: If you are transmitting jumbo frames, allow at least
ten seconds after starting the test to reach the bandwidth
specified.
11 If you enabled the Latency (RTD) test, go to the Latency
menu, then specify the number of trials, trial duration, and
show pass/fail status settings.
12 If you enabled the Packet Jitter test, go to the Jitter menu,
then specify the number of trials, trial duration, and show
pass/fail status settings.
13 If you enabled the System Recovery test, go to the
System Recovery menu, then specify the number of trials
and overload duration (at least 60 seconds).
14 If you enabled the Frame Loss test, go to the Frame Loss
menu, then specify the test procedure (RFC 2544, top
down, or bottom up), the trial duration, and the test granu-
larity settings.
15 If you enabled the Back to Back Frames test, go to the
Back to Back menu, then specify the number of trials,
burst granularity, and maximum trial time
16 If you indicated that you want to run the Asymmetrical
RFC in Combined mode, repeat
step 7 on page 216
through step 15 on page 217 for the downstream tests.