Appendix A Test Results
Auto-Neg Stats results
HST-3000 Ethernet Testing User’s Guide
297
Auto-Neg Stats results
The Auto-Neg Status category displays results associated
with the auto-negotiation of capabilities between the HST and
an Ethernet devices or two HSTs. Results in this category
appear after you turn auto-negotiation ON on your HST(s),
connect the HST(s) to the circuit, and then initialize the link.
Table 35 describes the results that appear in the Auto-Neg
Status category when testing 10/100/1G electrical Ethernet
service.
Table 35 Electrical Auto-Neg Stats test results
Result Description
1000Base-T FDX Indicates whether the Ethernet link
partner is full duplex capable at
1000Base-TX (YES or NO).
1000Base-T HDX Indicates whether the Ethernet link
partner is half duplex capable at
1000Base-TX (YES or NO).
100Base-TX FDX Indicates whether the Ethernet link
partner is full duplex capable at
100Base-TX (YES or NO).
100Base-TX HDX Indicates whether the Ethernet link
partner is half duplex capable at
100Base-TX (YES or NO).
10Base-T FDX Indicates whether the Ethernet link
partner is full duplex capable at
10Base-TX (YES or NO).
10Base-T HDX Indicates whether the Ethernet link
partner is half duplex capable at
10Base-TX (YES or NO).
Duplex Indicates the negotiated duplex setting
for the link (half or full).
Flow Control Indicates the negotiated flow control
capabilities.