164
BoomLiftModels X20JPLUS
MAINTENANCE
MUX20JP021602
12.10.HYDRAULICOILLEVELCHECK
Checktheoillevelonindicator;theoilmustbehalfwayupthelevelindicator.If
thisisnotthecase,topupthroughtherelativecap.Forthecharacteristicsofthe
hydraulicoiltobeusedseetherelativeparagraphʺTableofrecommendedlbrifi
cants(p. 139)ʺ.
12.11
.CHECKINGFORLEAK SINTHEHYDRAULICSYSTEM
Visuallycheckallhoses,connectionsandallothercomponentsinthehydraulic
system,inordertoidentifyanypossibleleaks.Leaksfromhosescannormallybe
resolvedbytighteningthefittings.Leaksfromgaskets(Orings,sealing ringsetc.)
cannotbe eliminatedbysimplytightening,asgask
etsusuallyleakbecausethey
aredamagedorhavebecomehard.Thecorrecttightnesscanonlyberestoredby
replacingthegasket.
12.12.CHECKINGTHECONDITIONOFTHEFILTERCARTRIDGE
Thecartridgemustbereplacedoneveryoilchangeandaccordingtotheintervals
specifiedinthemaintenancetable.
Thecheckmustbecarriedoutwiththemachi
neandthestabilisersinthere
stingpositiononflatground.
Fig.164 Hydraulicoillevelindicator Fig.165 Hydraulicoiltankcap