82
BoomLiftModels X20JPLUS
USINGTHEMACHINE
MUX20JP021602
11.USINGTHEMACHINE
11.1.SAFETYSTANDARDSTOADOPTBEFOREUSINGTHEPLATFORM
11.1.1.Riskofelectrocution
Ifthemachinemustbeusednearelectricpowerlines,theusermustremainata
suitabledistancefromthelatter.Thetablebelowsuppliesthevaluesrelatingto
theminimumdistancefromelectricpowerlinesdependingonthetypeofvolta‐
ge.
11.1.2.
Dangerduetoatmosphericconditions
DONOTWORKINUNFAVOURABLEATMOSPHERICCONDITIONS
Donotworkinthepresenceofstorms,snow,fogorwindexceeding12m/s.Do
not operate the machine when the ambient temperature drops below‐20°C or
SAFETYDISTANCEFROMPOWERLINES
LINERATEDVOLTAGE SAFETYDISTANCE(ME‐
TRES)
FROM TO
0V300V5
300V5
0KV 5
50KV 200KV 5
200KV 350KV 6.1
350KV 500KV 7.6
500KV 750KV 10.7
750KV 1000KV 13.7
Keepasafedi stancefrommainspowerlinesandelectricalsystems,
consideringthepossiblerangeofmovementofthemachineandits
oscillation,aswellasthepossibleoscillationofthepowerlines.
Before starting operation, examine the wo
rk area, taking note of
overhead power lines, moving machinery,such as overhead cranes
androad,railandbuildingequipment.