178
BoomLiftModels X20JPLUS
MAINTENANCE
MUX20JP021602
maybehaveasaprojectile.Theelectrolyteinsidethecellmaycauseveryserious
irritationtotherespiratorytract,eyesandskin.Inaddition,ventingmaycause
theemissionofhighly corrosivevapoursintheworkenvironment.Inthiscase,
all protectiveequipment suited to limit exposure to toxic fumes must be avai
lab
le.
MINIMUMEQUIPMENTREQUIRED:
•ClassDfireextinguisher
•Eyeprotectionorfaceshield
•Respiratorwithfilterforhydrochloricacidandsulphurdioxide
Neoprenegloves
•Acidresistantlabcoats
Bakingsoda,calciumoxideoracidabsorbentinkitform
•Vermiculite
•Plasticbags
PROCEDURE:
Intheeventofelectrolytereleasefromthecells,proceedasfollows:
Evacuatethepeopleexpose
dtofumesfromthearea.
•Airtheenvironmentunt ilthecompleteremovalof thecellanduntilthecha
racteristicpungentodourhasdisappeared.
•Ifthecellistoohot,allowittocooltoambienttemperaturebeforehandlingit.
•Wearsafetyequipment:coat,gloves,maskandfilters,andmoveth
ecelltoa
wellventilatedarea.
•Placeeverycellinasealableplasticbagandremovetheexcessair,thenseal
thebag.
•Placeacupofvermiculiteinasecondbag,placethefirstbaginthesecondand
sealit.
•Placeeverythinginathirdbagwithsomesodaandsealthebag.
•A
bsorbandcollecttheleak ed electrolytewithabsorbentmaterialorsoda.
•Placetheabsorbentmaterialinabagandsealit.
•Cleantheareawithplentyofwater.
•Disposeofthehazardousmaterialinaccordancewiththelocallegislati onin
force.
FIRSTAIDINTHEEVENTOFCONTACTWITHTHEELECTROLYTE: