Table 48: Estimated Values for Factors Causing Link Loss (continued)
Estimated Link-Loss ValueLink-Loss Factor
Single-mode—None
Multimode—None, if product of bandwidth and distance
is less than 500 MHz-km
Modal and chromatic dispersion
0.5 dBConnector
0.5 dBSplice
Single-mode—0.5 dB/km
Multimode—1 dB/km
Fiber attenuation
The following example uses the estimated values in Table 48 on page 96 to calculate
link loss (LL) for a 2-km-long multimode link with a power budget (P
B
) of 13 dB:
Fiber attenuation for 2 km @ 1.0 dB/km = 2 dB
Loss for five connectors @ 0.5 dB per connector = 5(0.5 dB) = 2.5 dB
Loss for two splices @ 0.5 dB per splice = 2(0.5 dB) = 1 dB
Higher-order mode loss = 0.5 dB
Clock recovery module = 1 dB
The power margin (P
M
) is calculated as follows:
P
M
= P
B
LL
P
M
= 13 dB 2 km (1.0 dB/km) 5 (0.5 dB) 2 (0.5 dB) 0.5 dB [HOL] 1 dB [CRM]
P
M
= 13 dB 2 dB 2.5 dB 1 dB 0.5 dB 1 dB
P
M
= 6 dB
The following sample calculation for an 8-km-long single-mode link with a power budget
(P
B
) of 13 dB uses the estimated values from Table 48 on page 96 to calculate link loss
(LL) as the sum of fiber attenuation (8 km @ 0.5 dB/km, or 4 dB) and loss for seven
connectors (0.5 dB per connector, or 3.5 dB). The power margin (P
M
) is calculated as
follows:
P
M
= P
B
LL
P
M
= 13 dB 8 km (0.5 dB/km) 7(0.5 dB)
P
M
= 13 dB 4 dB 3.5 dB
P
M
= 5.5 dB