DCE80-100E
Technical Handbook
Operator’s cab
Service
8
P.Group 10
TDCE01
04GB
Changing the fresh air filter
(every 200 hours or when needed)
1. Remove the filter casing retaining bolts and remove the filter
element.
2. Wash the filter insert with water and detergent or by using a
high pressure washer. Replace the insert if necessary.
3. Reinstall the filter insert.
Checking condensate draining
1. On certain machines with air conditioning system, there are
two hoses for draining of condensate from the condensor.
The hoses can be found on the underside of the cab’s front,
see illustration.
2. Check that the hoses are hanging so that there can be no
water accumulation. A bend can create a water lock which
will prevent the drainage.
KL1839