4 Remote Interface Reference
188 Keysight 33210A User’s Guide
APPLy?
Query the function generator’s current configuration and return a quoted string.
The purpose of this command is to allow you to append this query response to an
APPL: command in your programming application and use the result to place the
function generator in the specified state. The function, frequency, amplitude, and
offset are returned as shown in the sample string below (the quotation marks are
returned as part of the string).
“SIN +5.0000000000000E+03,+3.0000000000000E+00,-2.5000000000000E+00”