Appendix
334
Command
:DATA[1|2]:ATTR:POIN?
Long
:DATA[1|2]:ATTRibute:POINts?
Parameters
[<arb name>]
Parameter Suffix
Description
Query the number of points in the specified arbitrary waveform. Returns a
value from 1 to Sample
max
points.
81150A: Sample
max
= 524288 (512 k)
81160A 1 channel: Sample
max
= 262144 (256 k)
81160A 2 channels: Sample
max
= 131072 (128 k)
The default arb-name is the arbitrary waveform currently active (selected
with FUNC:USER command).
If you query a waveform that is not currently stored in memory, a “Specified
arb waveform does not exist error is generated.
Example
:DATA:ATTR:POIN? EXP_RISE
Response
1.63840E+04