Appendix
98
Characteristics
Trigger Frequency 81150A: 1 Hz to 120 MHz (default 100 kHz)
Trigger Frequency 81160A: 1 Hz to 330 MHz (default 100 kHz)
Trigger Period 81150A: 8.3333 ns to 1000000s (default 10 s)
Trigger Period 81160A: 3.03 ns to 1000000s (default 10 s)
The trigger period setting is used only when Internal triggering is
enabled. The trigger period is ignored when manual or external
triggering is enabled (or when the gated mode is selected).
It is not possible to specify a trigger period which is too short for the
81150A / 81160A to output with the specified burst count and
frequency (see below).
Trigger Period > Burst Count x Waveform Period
It is not possible to specify a trigger period which is too short for the
81150A / 81160A to output with the specified sweep time.
Trigger Period > Sweep Time
Front Panel
Operation
To set the trigger period, press the Internal Period or Internal Frequency
softkey and then use the knob or numeric keypad to enter the period.
Remote Interface
Operation
:ARM:FREQuency[1|2] {<frequency>|MINimum|MAXimum}
:ARM:PERiod[1|2] {<seconds>|MINimum|MAXimum}

Table of Contents

Related product manuals