Features and Functions
81150A and 81160A User’s Guide 93
Gated
The gated mode is very closely related to the Triggered mode. The
instrument continuously generates the selected waveform, sweep, or burst
while the selected gate is still active.
If the gate is getting inactive, the current cycle will be finished.
If the gate is getting active again while the previous cycle is being finished,
then there will be no discontinuity at the outputs.
Front Panel
Operation
Press the , , or the key to select the desired trigger
mode. Pressing the illuminated key on the Front Panel will show the Trigger
Mode screen.
Remote Interface
Operation
To select continuous mode:
:ARM:SOURce {IMMediate}
To select triggered mode:
:ARM:SOURce {INTernal2|EXTernal|MANual}
:ARM:SOURce {EDGE}
To select gated mode:
:ARM:SOURce {EXTernal|MANual}
:ARM:SENSe {LEVel}