34 PWR-01
Measured Value Display and Setting Display
The voltage and current displays have the following two states.
• Measured value display
• Setting display
In addition to the voltmeter and ammeter, the PWR-01 can display the power, the set OVP,
OCP, or UVL, and the system configuration.
Measured value display
The present output voltage and output current are displayed.
In this situation, the SET key is off.
You can change the output voltage and output current in the
measured value display (p.43).
Power display
In the measured value display, press PWR DSPL to display
the output voltage in the voltmeter and the output power on
the ammeter. The output power is calculated from the mea-
sured output voltage and the measured output current.
When the power is being displayed, the PWR DSPL key
lights. If you press the key again, the light turns off, and the
output current is displayed.
Setting display
Press SET to light the key and display the present output volt-
age and output current settings.
Pressing SET again turns off the key and shows the mea-
sured value display.
Overvoltage protection, overcurrent protection, and undervoltage limit set-
ting display
Press OVP•OCP to light the key and display the present
overcurrent protection and overvoltage protection settings.
Press OVP•OCP again, the present undervoltage limit value
is displayed.
CV
CC
/
W
V
A
AL M RMT LOCK LAN
BCA
PRESET
DLY SEQ HBSSVIR
CV
CC
/
W
V
A
AL M RMT LOCK LAN
SC2 SC3 LOCKALM CLR SC1
SHIFT
FINE
FINE
REGULA TED DC POWER SUPPLY
OUTPUT
VOLTAGE
CURRENT
CONFIG
PWR DSPLMEMORY
LOCALSET OVP•OCP
CV
CC
/
W
V
A
AL M RMT LOCK LAN
BCA
PRESET
DLY SEQ HBSSVIR
CV
CC
/
W
V
A
AL M RMT LOCK LAN
SC2 SC3 LOCKALM CLR SC1
SHIFT
FINE
FINE
REGULA TED DC POWER SUPPLY
OUTPUT
VOLTAGE
CURRENT
CONFIG
PWR DSPLMEMORY
LOCALSET OVP•OCP
Lit
Output
Power
Output
Voltage
CV
CC
/
W
V
A
AL M RMT LOCK LAN
BCA
PRESET
DLY SEQ HBSSVIR
CV
CC
/
W
V
A
AL M RMT LOCK LAN
SC2 SC3 LOCKALM CLR SC1
SHIFT
FINE
FINE
REGULA TED DC POWER SUPPLY
OUTPUT
VOLTAGE
CURRENT
CONFIG
PWR DSPLMEMORY
LOCALSET OVP•OCP
CV
CC
/
W
V
A
AL M RMT LOCK LAN
BCA
PRESET
DLY SEQ HBSSVIR
CV
CC
/
W
V
A
AL M RMT LOCK LAN
SC2 SC3 LOCKALM CLR SC1
SHIFT
FINE
FINE
REGULA TED DC POWER SUPPLY
OUTPUT
VOLTAGE
CURRENT
CONFIG
PWR DSPLMEMORY
LOCALSET OVP•OCP
Lit
OCP
Trip points
OVP
Trip points
CV
CC
/
W
V
A
AL M RMT LOCK LAN
BCA
PRESET
DLY SEQ HBSSVIR
CV
CC
/
W
V
A
AL M RMT LOCK LAN
SC2 SC3 LOCKALM CLR SC1
SHIFT
FINE
FINE
REGULA TED DC POWER SUPPLY
OUTPUT
VOLTAGE
CURRENT
CONFIG
PWR DSPLMEMORY
LOCALSET OVP•OCP
Lit
ÕÖÌ
Trip point