54 PWR-01
CONFIG Settings
Use the CONFIG settings to set the PWR-01 system configuration. You can set and display
the following parameters in the CONFIG settings.
Effect: ● indicates that the parameter is affected when the panel settings are reset (CF00).
■ indicates that the parameter may be affected when the LAN interface settings are reset
(CF60: LCI/ DEF).
Note:
○ indicates that the change is immediately applied
△ indicates that the change is applied the next time the power is turned on
◇ indicates that the change is applied when CF60: APPL is executed
Display
switching
Parameter
number
Mnemonic Setting/ display Effect Note
Basic CF00 RSE Reset Resets the panel settings
—
○
CF01
1
BLE Bleeder Sets the bleeder circuit
—
○
CF02 PRIO Priority Output-on startup state
—
○
CF03 VIR V.I.R Internal resistance setting (VIR)
●○
CF04 SS.C.R S.Start CCrise Soft start time (CC mode)
●○
CF05 SS.C.F S.Stop CCfall Soft stop time (CC mode)
●○
CF06 SS.V.R S.Start CVrise Soft start time (CV mode)
●○
CF07 SS.V.F S.Stop CVfall Soft stop time (CV mode)
●○
CF08 ON.D On delay Output-on delay setting
●○
CF09 OFF.D Off delay Output-off delay setting
●○
CF10 E.CC Ext. CC CC control using an external voltage/ external resistance
●○
CF11 E.CV Ext. CV CV control using an external voltage/ external resistance
●○
CF12 E.RNG Control range CV/ CC control range
—
○
CF13
1
M.RNG Monitor range Voltage/ Current monitor output range
—
○
CF14 E.OUT Ext. on/ off External control for turning output on/ off
●○
CF15 E.LOG Ext. logic External control logic for turning output on/ off
—
○
CF16 STS.C Stat. CC. pol CC status signal polarity
—
○
CF17 STS.V Stat. CV. pol CV status signal polarity
—
○
CF18 STS.O Stat. Output. pol Output status signal polarity
—
○
CF19 STS.A Stat. Alarm. pol Protection function/ alarm status signal polarity
—
○
Alarm
CF20
1
A.RCV Alarm recovery Output when AC-FAIL protection is released
—
△
CF21 WDOG Watchdog Communication monitoring (WATCHDOG) timer
—
○
CF22 CC.LA CC limit auto Current setting limit
●○
CF23 CV.LA CV limit auto Voltage setting limit
●○
CF24
1
OC.DL OCP delay Detection time of OCP activation
—
○
Usability CF30 SC1 Short cut 1 CONFIG parameter shortcut registration (SC1)
—
○
CF31 SC2 Short cut 2 CONFIG parameter shortcut registration (SC2)
—
○
CF32 SC3 Short cut 3 CONFIG parameter shortcut registration (SC3)
—
○
CF33 BEEP Beep Buzzer on/ off
—
○
CF34
1
BRI
Brightness Panel display brightness
—
○
CF35 AMTR Ammeter Slave unit display during master-slave parallel operation
—
○
System CF40 LAN LAN LAN interface setting
■
2
△
CF41 USB USB USB interface setting
—
△
CF42 232 RS232C RS232C interface setting
—
△
CF43 TRAC Trace SCPI communication error display
—
○
CF44
1
PARA Parallel Master-slave parallel operation
—
△
CF45 PON Power on Output state at power-on
—
△