54 PWR-01
CONFIG Settings
Use the CONFIG settings to set the PWR-01 system configuration. You can set and display
the following parameters in the CONFIG settings.
Effect: indicates that the parameter is affected when the panel settings are reset (CF00).
indicates that the parameter may be affected when the LAN interface settings are reset
(CF60: LCI/ DEF).
Note:
indicates that the change is immediately applied
indicates that the change is applied the next time the power is turned on
indicates that the change is applied when CF60: APPL is executed
Display
switching
Parameter
number
Mnemonic Setting/ display Effect Note
Basic CF00 RSE Reset Resets the panel settings
CF01
1
BLE Bleeder Sets the bleeder circuit
CF02 PRIO Priority Output-on startup state
CF03 VIR V.I.R Internal resistance setting (VIR)
●○
CF04 SS.C.R S.Start CCrise Soft start time (CC mode)
●○
CF05 SS.C.F S.Stop CCfall Soft stop time (CC mode)
●○
CF06 SS.V.R S.Start CVrise Soft start time (CV mode)
●○
CF07 SS.V.F S.Stop CVfall Soft stop time (CV mode)
●○
CF08 ON.D On delay Output-on delay setting
●○
CF09 OFF.D Off delay Output-off delay setting
●○
CF10 E.CC Ext. CC CC control using an external voltage/ external resistance
●○
CF11 E.CV Ext. CV CV control using an external voltage/ external resistance
●○
CF12 E.RNG Control range CV/ CC control range
CF13
1
M.RNG Monitor range Voltage/ Current monitor output range
CF14 E.OUT Ext. on/ off External control for turning output on/ off
●○
CF15 E.LOG Ext. logic External control logic for turning output on/ off
CF16 STS.C Stat. CC. pol CC status signal polarity
CF17 STS.V Stat. CV. pol CV status signal polarity
CF18 STS.O Stat. Output. pol Output status signal polarity
CF19 STS.A Stat. Alarm. pol Protection function/ alarm status signal polarity
Alarm
CF20
1
A.RCV Alarm recovery Output when AC-FAIL protection is released
CF21 WDOG Watchdog Communication monitoring (WATCHDOG) timer
CF22 CC.LA CC limit auto Current setting limit
●○
CF23 CV.LA CV limit auto Voltage setting limit
●○
CF24
1
OC.DL OCP delay Detection time of OCP activation
Usability CF30 SC1 Short cut 1 CONFIG parameter shortcut registration (SC1)
CF31 SC2 Short cut 2 CONFIG parameter shortcut registration (SC2)
CF32 SC3 Short cut 3 CONFIG parameter shortcut registration (SC3)
CF33 BEEP Beep Buzzer on/ off
CF34
1
BRI
Brightness Panel display brightness
CF35 AMTR Ammeter Slave unit display during master-slave parallel operation
System CF40 LAN LAN LAN interface setting
2
CF41 USB USB USB interface setting
CF42 232 RS232C RS232C interface setting
CF43 TRAC Trace SCPI communication error display
CF44
1
PARA Parallel Master-slave parallel operation
CF45 PON Power on Output state at power-on