10.4 Motor choke 3YL-24
Technical data:
Rated data Sym Unit 3 YL-24
Rated Current I0rms A Max.3x 24
Frequency fmax kHz 8.3
Inductivity L µH 120
Resistance R mOhm 2.6
Weight G kg 1.4
Cable diameter (Shield clamp) - mm 4 to 13.5
Wire cross section U-V-W max. (terminals) - mm² 4
Wire cross section BR+/- max. (terminals) - mm² 2.5
Accessories Europe | 10 Motor chokes
Kollmorgen | December 2014 43