Accessories Europe | 11 îîCables
Preparing cables for terminal box, combined cables (AKM8, DBL7/8)
Remove the outer covering
over length B, without dam-
aging the shielding braid.
Shorten the shielding braid
to length A.
Push the union nut (1) and
the clamping ring (2) onto
the cable and push the
shielding braid back over
the clamping ring. The
shielding braid must cover
the sealing ring (3), but must
not stick out over the sealing
edge (4). Cut off the cores to
lengths C/D/E. Shorten the
shielding braid for the brake
cores to length A.
Push the shielding braid for
the brake cores back over
the clamping ring. The braid
must cover the sealing ring
(3) but must not stick out
over the sealing edge (4).
Screw the threaded sleeve (5) into the terminal box (6, example: AKM8 Motor). Push the
cores of the cable and the clamping ring (2) through the threaded sleeve and screw the union
nut (1) tightly onto the threaded sleeve.
Then fit, depending on the motor type, bootlace ferrules or ring terminals to the ends of the
cores.
Motor A B C D E Connection
DBL7/8 20 140 110 130 140 Terminals
AKM8 20 140 110 130 140 Terminals
76 Kollmorgen | December 2014